5.0 W IRING T HE M ETER
WIRING OVERVIEW
Electrical connections are made to the #22 AWG colored wires protruding
from the rear of the unit. When using the optional terminal block, the #22 AWG
colored wires are cut off and electrical connections are made via screwless type
terminal block. All conductors should conform to the meter ’s voltage and
current ratings. All cabling and wire terminations should conform to appropriate
standards of good installation, local codes and regulations. It is recommended
that the backlight power supplied to the meter (DC or AC) be protected by a fuse
or circuit breaker.
EMC INSTALLATION GUIDELINES
Although this meter is designed with a high degree of immunity to Electro-
Magnetic Interference (EMI), proper installation and wiring methods must be
followed to ensure compatibility in each application. The type of the electrical
noise, source or coupling method into the meter may be different for various
installations. The meter becomes more immune to EMI with fewer I/O
connections. Cable length, routing, and shield termination are very important
and can mean the difference between a successful or troublesome installation.
Listed below are some EMC guidelines for successful installation in an
industrial environment.
1. The meter should be mounted in a metal enclosure, which is properly
connected to protective earth.
2. Use shielded (screened) cables for all Signal and Control inputs. The shield
(screen) pigtail connection should be made as short as possible. The
connection point for the shield depends somewhat upon the application.
Listed below are the recommended methods of connecting the shield, in order
of their effectiveness.
a. Connect the shield only at the panel where the unit is mounted to earth
ground (protective earth).
b. Connect the shield to earth ground at both ends of the cable, usually when
the noise source frequency is above 1 MHz.
c. Connect the shield to common of the meter and leave the other end of the
shield unconnected and insulated from earth ground.
3. Never run Signal or Control cables in the same conduit or raceway with AC
power lines, conductors feeding motors, solenoids, SCR controls, and
heaters, etc. The cables should be ran in metal conduit that is properly
grounded. This is especially useful in applications where cable runs are long
and portable two-way radios are used in close proximity or if the installation
is near a commercial radio transmitter.
4. Signal or Control cables within an enclosure should be routed as far as possible
from contactors, control relays, transformers, and other noisy components.
5. In extremely high EMI environments, the use of external EMI suppression
devices, such as ferrite suppression cores, is effective. Install them on Signal
and Control cables as close to the unit as possible. Loop the cable through the
core several times or use multiple cores on each cable for additional protection.
Install line filters on the power input cable to the unit to suppress power line
interference. Install them near the power entry point of the enclosure. The
following EMI suppression devices (or equivalent) are recommended:
Ferrite Suppression Cores for signal and control cables:
Fair-Rite # 0443167251 (RLC# FCOR0000)
TDK # ZCAT3035-1330A
Steward # 28B2029-0A0
Line Filters for input power cables:
Schaffner # FN610-1/07 (RLC# LFIL0000)
Schaffner # FN670-1.8/07
Corcom # 1 VR3
Note: Reference manufacturer ’s instructions when installing a line filter.
6. Long cable runs are more susceptible to EMI pickup than short cable runs.
Therefore, keep cable runs as short as possible.
7. Switching of inductive loads produces high EMI. Use of snubbers across
inductive loads suppresses EMI.
Snubber: RLC# SNUB0000.
USING THE COLOR CODED WIRES
The low voltage input units will contain three or four color coded wires
depending on the backlight power requirements.
The high voltage input units will contain (2) orange wires and an additional
two or three wires depending on the backlight power requirements.
The tables define the function of each colored wire.
WHITE
Low Voltage Input
LOW VOLTAGE INPUT
Wire Colors
BLUE BLACK
Reset Common
RED
+Backlight Power
HIGH VOLTAGE INPUT
Wire Colors
ORANGE
High Voltage
Input
ORANGE
High Voltage
Input
BLUE
Reset
BLACK
Common
RED
+Backlight
Power
TERMINAL BLOCK OPTION
CONNECTIONS : Wire clamping terminals
Wire Strip Length: 0.275" (7 mm)
Wire Gage: 24-16 AWG copper wire
1 2 3
1 2 3 4
1 2 3 4 5
5
相关PDF资料
5330H5-5V LED T1-3/4 GREEN 562NM VAR HT
5330H1-5V LED T1-3/4 RED 635NM VAR HT
ASD3-25.000MHZ-ECT OSCILLATOR 25.000 MHZ 1.8V SMD
5307H5-5V LED T1-3/4 GREEN 656NM RA PCB
CUB7P220 COUNTER 8-DIGIT LOGIC RED
5307H3-5V LED T1-3/4 AMBER 583NM RA PCB
CUB7P210 COUNTER 8-DIGIT LOGIC GREEN
5307H1-5V LED T1-3/4 RED 635NM RA PCB
相关代理商/技术参数
CUB7P320 功能描述:COUNTER 8-DIGIT LV RED BACKLIGHT RoHS:是 类别:工业控制,仪表 >> 计数器 系列:CUB7 其它有关文件:Declaration of Conformity 标准包装:1 系列:99766 计数速率:25Hz 数字/字母数:5 输入类型:机电式脉冲 输出类型:- 电源电压:24V 显示器类型:十进制拨轮
CUB7T000 功能描述:TIMER LCD PROGRAM 8 DIGIT RoHS:是 类别:工业控制,仪表 >> 定时器 系列:CUB7 标准包装:10 系列:- 计时范围:- 工作模式:累积 输出类型:- 电源电压:4.5 V ~ 10 V 端接类型:PCB 引脚 显示器类型:无显示器 其它名称:2001PC-001 5VDCQ1273012Q1443992
CUB7T100 功能描述:TIMER LCD PROGRAM V IN 8 DIGIT RoHS:是 类别:工业控制,仪表 >> 定时器 系列:CUB7 标准包装:10 系列:- 计时范围:- 工作模式:累积 输出类型:- 电源电压:4.5 V ~ 10 V 端接类型:PCB 引脚 显示器类型:无显示器 其它名称:2001PC-001 5VDCQ1273012Q1443992
CUB7T120 制造商:Red Lion Controls 功能描述:ELECTRONIC TIMER VOLTAGE RED LCD
CUB7TCG0 功能描述:TIMER LCD PROGRAM 8-DIGIT LV GRN RoHS:是 类别:工业控制,仪表 >> 定时器 系列:CUB7 标准包装:10 系列:- 计时范围:- 工作模式:累积 输出类型:- 电源电压:4.5 V ~ 10 V 端接类型:PCB 引脚 显示器类型:无显示器 其它名称:2001PC-001 5VDCQ1273012Q1443992
CUB7TCG1 制造商:Red Lion Controls 功能描述:TIMER SOURCE GREEN DISPLAY 8-DIGIT 制造商:Red Lion Controls 功能描述:TIMER LCD GREEN DIS .001S-1H PAN
CUB7TCR0 功能描述:TIMER LCD PROGRAM 8-DIGIT LV RED RoHS:是 类别:工业控制,仪表 >> 定时器 系列:CUB7 标准包装:10 系列:- 计时范围:- 工作模式:累积 输出类型:- 电源电压:4.5 V ~ 10 V 端接类型:PCB 引脚 显示器类型:无显示器 其它名称:2001PC-001 5VDCQ1273012Q1443992
CUB7TCR1 制造商:Red Lion Controls 功能描述:TIMER SOURCE RED DISPLAY 8-DIGIT 制造商:Red Lion Controls 功能描述:TIMER LCD RED DISP .001S-1H PAN